FORMAT_EN_2023-25_WCT_Light

All prices quoted are non-binding recommended prices. 5/102 Design: With automatic test run, secure measurement connection even for PV system energy supply. Measured data storage for 999 photovoltaic strings, USB interface for measured data download. Integrated real time clock to save measured data with date and time stamp. Measurement of the currentvoltage characteristic (I-V) and power characteristic (P-V). Direct connection to all standard PV modules with MC4 or Sunclix plug connector. Application: For installation and repeat testing of grid-connected photovoltaic systems in accordance with VDE 0126-23 (DIN EN 62446) and DIN EN 61829 (VDE 0126-24) to verify performance data. Suitable for solar engineers(commissioning, repeat tests, trouble-shooting), photovoltaic experts as well as service, cleaning and maintenance teams. Scope of delivery: Test device, test leads, crocodile clips, MC4/Sunclix test leads, PC software, micro USB cable, bag and batteries. Protective conductor resistance 0.05 Ohm–199 Ohm Insulation resistance 0.05 MOhm–199 MOhm Off-load voltage (direct current) 5 V–1000 V Short-circuit current (direct current) 0.5 A–15 A Voltage 30 V–440 V Measurement value memory 999 Batteries 6 x Mignon AA/LR6 5586 € C (W511) Order No. …0800 Photovoltaic installation tester PV 2 SET m IP40 USB Design: To produce test reports and document the performance data of the PV generator: Pmpp, Uoc, Umpp, Isc, Impp, fullness factor, temperature and the solar irradiation. Documentation of the measured IU characteristic (voltage) and performance curve (power supply) from the PV 2 photovoltaic installation tester. STC calculation and performance comparison via integrated PV module database. Application: For compiling test reports and documentation according to standards DIN EN 62446 (VDE 0126-23) and DIN EN 61829 (VDE 0126-24). 5586 Order No. € 246.50 …0700 (W511) PC software SOLAR Manager for photovoltaic installation tester and characteristic curve measuring device PV 2 Design: With calibrated photovoltaic reference cell for precise measurement of solar irradiation, 2-channel temperature sensor, digital compass, data logger for irradiation, module/ambient temperature, date/time stamp with real time clock and adjustable measuring interval (1–60 minutes), radio link with approx. 30 m range in the open area to photovoltaic installation tester BENNING PV 1-1 and PV 2, as well as USB interface for measurement value download. Application: Ideal for planning,commissioning and repeat tests on photovoltaic systems hooked up to the mains according to VDE 0126-23 (DIN EN 62446) and for testing thermal solar plants (solar heat). Suitable for solar engineers(commissioning, repeat tests, trouble-shooting, cost-benefit tests), photovoltaic experts as well as service, cleaning and maintenance teams. For measuring solar irradiation, photovoltaic module and ambient temperature, compass point and angle of inclination. Scope of delivery: Measuring device, calibration certificate, case, rubber case, module/ambient temperature sensor, USB cable, reading software (CD) and batteries. Solar irradiation 100–1250 W/m2 Temperature (module/environment) –30 °C to +125 °C Compass bearing (direction) 0°–360° Inclinometer 0°–80° Real-time clock Date/time stamp Measurement value memory 5000 Dimensions (L x W x H)/weight 150 x 80 x 33 mm/347 g Batteries 2 x Mignon AA/LR6 5586 € 484.50 (W511) Order No. …0400 Irradiation and temperature measurement device SUN 2 IP40 USB Test and measuring devices 5

RkJQdWJsaXNoZXIy NTg4MTI=