FORMAT_EN_2023-25_WCT_Light

All prices quoted are non-binding recommended prices. 9/10 Cable length m Conductor cross-section mm 9023 9026 9071 9074 9028 9022 Order No. € € € € € € 5 1.5 C C – – C – …0050 10 1.5 C C C C C C …0100 10 2.5 – – C C C C …1100 15 1.5 – C – – – – …0150 20 1.5 – C – – – – …0200 25 1.5 – C C C C C …0250 25 2.5 – – C C C C …1250 ​ (W909) (W909) (W909) (W909) (W904) (W909) Extension cables IP44 9022 9022 With LED signal when voltage is applied. 9028 9023 + 9026 9023 Cable type rubber H05 RR-F 3G, with safety plug and coupling with flat-top cover. Suitable for use indoors as well as for short-term use outdoors. 9026 Cable type neoprene H07 RN-F 3G, with safety plug and coupling with flat-top cover. For indoor and permanent outdoor use. 9071 Cable type neoprene H07 RN-F 3G, with solid rubber safety plug and coupling with flat-top cover. For indoor and permanent outdoor use. 9074 Cable type neoprene H07 RN-F 3G, with solid rubber safety plug and coupling with flat-top cover. Heavy design. For indoor and permanent outdoor use. 9028 Cable type polyurethane H07 BQ-F 3G, with safety plug and coupling including closure cap. The BREMAXX®-PUR cable (BQ cable) is extremely abrasion-resistant, resistant to overrolling and has a very high cutting and tear resistance. It is also resistant to acid and oil, and weather- and microbe-resistant. Cold resistant down to -40 °C. Suitable for use indoors, permanent use outdoors and on industrial construction sites. 9022 Cable type polyurethane H07 BQ-F 3G, with safety plug and coupling including closure cap 250 V/10-16 A. Safety plug with LED light as voltage display. PUR cable (polyurethane cable H07BQ-F) is extremely abrasion-resistant, resistant to overrolling and has a very high cutting and tear resistance. It is also resistant to acid and oil, and weather- and microberesistant. Temperature range –40 °C to +80 °C. Suitable for use indoors, permanent use outdoors and on industrial construction sites. 9074 0100 9071 Design: Cable type neoprene H07 RN-F 3G2.5, with safety plug and coupling with flat-top cover. Application: For protection against accidents due to missing socket outlets. Checking the socket when switching on, interruption of the L and N conductor if a fault is detected, such as wiring fault, over- and undervoltage, PE or N conductor interruption. The protective conductor circuit remains closed. Detects measurement errors, such as those that occur when wearing work gloves during the test, and does not switch on. For indoor and permanent outdoor use. Cable length m Nominal current mA Trip current mA 9025 Order No. € 1.5 + 1.5 16 30 C …1030 ​ (W909) Personal protection switch PRCD-S+ m IP44 Power distributors 9

RkJQdWJsaXNoZXIy NTg4MTI=